Evidence and safety contract
This is anonymized historical case evidence, not a universal installation procedure. Preserve each case's status, equipment, scope and cautions. A Solved label is not proof. Do not invent a successful outcome or transfer a fix to a similar case.
For a question about a specific case number, use only the entry with that exact case reference. If it is not in the retrieved material, say the case cannot be verified; never substitute a similar case or infer a cause. A documented outcome means the recorded technical result was successful within its scope, not that a lifetime guarantee or independent retest exists. Do not invent missing-verification warnings that contradict a recorded successful result.
ELConfig is for analog Ethernet Link units; VCT is for Vertex. ATA FXS analog outputs must never connect to Vertex Ethernet. Missing readable SIP does not prove encryption, and UDP does not automatically mean SIP. A canceled ringing branch or SIP dialog BYE does not establish that the outside call ended or the CallerID device sent End. Correlate actual device-to-POS output.
Use current manufacturer/provider guidance. Historical firmware, DIP, address and port settings are site/model specific. Do not reproduce blanket firewall disabling, Internet forwarding, shared/reset credentials or unapproved resets as generic fixes. Escalate uncertain cases and preserve normal phone service.
Serial, USB, COM ports and driver compatibility
Cases are grouped for navigation only. Root causes and remedies are not shared automatically between members.
Case #2718: Documented technical outcome
Exact source reference: support case #2718. Evidence classification: Documented technical outcome. This paragraph and the following fields concern only case #2718, not another case with similar symptoms.
Problem: CID failing at customer site despite working at technician's home.
Recorded action: Set SIP gateway and addressed serial port configuration.
Recorded result: System working.
Scope: Serial port and SIP gateway.
Recorded equipment/software: [21000-4] Vertex (4)
Case #2718 actual source outcome: Set the SIP gateway, and after remembering it is serial port based, all is working. The note records successful operation after that configuration; do not relabel this recorded outcome unresolved merely because it is historical rather than a new independent site test.
Provenance: Odoo support record 46; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #2722: Action recorded: resolution NOT established
Exact source reference: support case #2722. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #2722, not another case with similar symptoms.
Problem: CID not working after server upgrade to Windows 11.
Recorded action: Updated serial-to-USB drivers and corrected COM port settings in software.
Recorded result: CallerID retrieved on one machine; escalation needed for multi-workstation push.
Scope: Serial communication.
Recorded equipment/software: [13000-A] WC4 Deluxe
Limits: Escalation required for remaining stations. Prior source review did not establish a reusable end-to-end resolution; retained as case evidence only.
Provenance: Odoo support record 50; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #2744: Unresolved: NOT a known fix
Exact source reference: support case #2744. Evidence classification: Unresolved: NOT a known fix. This paragraph and the following fields concern only case #2744, not another case with similar symptoms.
Problem: Setup mode did not work with POS.
Recorded action: Installed Vertex in-line with Poly Rove 30 base station.
Recorded result: Unable to confirm if setup mode worked; customer referred to check Harbor Touch requirements.
Scope: Vertex install.
Recorded equipment/software: [21000-4] Vertex (4)
Limits: No successful outcome confirmed.
Provenance: Odoo support record 72; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #2751: Action recorded: resolution NOT established
Exact source reference: support case #2751. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #2751, not another case with similar symptoms.
Problem: Setup mode/Serial port issues with Pulse POS.
Recorded action: Switched from Serial to Ethernet/UDP.
Recorded result: Pulse set the reception to Ethernet and all is working.
Scope: Integration/Installation.
Recorded equipment/software: [21000-2] Vertex (2)
Limits: Prior source review did not establish a reusable end-to-end resolution; retained as case evidence only.
Provenance: Odoo support record 79; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #2756: Action recorded: resolution NOT established
Exact source reference: support case #2756. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #2756, not another case with similar symptoms.
Problem: POS receiving excessive/no usable data over serial/UDP.
Recorded action: Set unit to UDP; coordinating with Pulse support.
Recorded result: Seen call data on Vertex Config over UDP, so we know the box is working.
Scope: POS/Integration.
Recorded equipment/software: [21000-4] Vertex (4)
Limits: POS-side data interpretation still an issue.
Provenance: Odoo support record 84; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #2761: Unresolved: NOT a known fix
Exact source reference: support case #2761. Evidence classification: Unresolved: NOT a known fix. This paragraph and the following fields concern only case #2761, not another case with similar symptoms.
Problem: Vertex not connecting to POS network.
Recorded action: Recommended checking USB driver and POS compatibility.
Recorded result: Pending customer troubleshooting.
Scope: Integration.
Recorded equipment/software: [21000-4] Vertex (4)
Limits: No success verification.
Provenance: Odoo support record 89; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #2820: Action recorded: resolution NOT established
Exact source reference: support case #2820. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #2820, not another case with similar symptoms.
Problem: Serial port required for installation is missing.
Recorded action: Verified operation in broadcast mode where computer sees incoming calls.
Recorded result: Installation not finalized due to hardware limitations.
Scope: Vertex serial port configuration
Recorded equipment/software: [21000-4] Vertex (4)
Limits: Installation not completed.
Provenance: Odoo support record 148; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #2846: Action recorded: resolution NOT established
Exact source reference: support case #2846. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #2846, not another case with similar symptoms.
Problem: Unit serial number not found; improper hardware for current VoIP system.
Recorded action: Advised customer to obtain Vertex box.
Recorded result: Identification of incompatible hardware.
Scope: Hardware compatibility
Recorded equipment/software: [54000] WC Deluxe (4, Ethernet)
Limits: Missing confirmed success.
Provenance: Odoo support record 174; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #2878: Documented technical outcome
Exact source reference: support case #2878. Evidence classification: Documented technical outcome. This paragraph and the following fields concern only case #2878, not another case with similar symptoms.
Problem: Device was offline due to incorrect port usage and output mode setting.
Recorded action: Corrected wiring (inline) and set output mode to serial.
Recorded result: Unit started working.
Scope: Networking and configuration
Recorded equipment/software: [21000-2] Vertex (2)
Provenance: Odoo support record 206; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #2912: Unresolved: NOT a known fix
Exact source reference: support case #2912. Evidence classification: Unresolved: NOT a known fix. This paragraph and the following fields concern only case #2912, not another case with similar symptoms.
Problem: Vertex stopped working; phone setup failed despite correct cable installation.
Recorded action: Attempted phone setup; requested customer procure USB-to-Ethernet adapter.
Recorded result: No resolution achieved; pending customer follow-up.
Scope: Vertex 2 connectivity
Recorded equipment/software: [21000-2] Vertex (2)
Limits: No actual resolution confirmed.
Provenance: Odoo support record 240; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #2938: Unresolved: NOT a known fix
Exact source reference: support case #2938. Evidence classification: Unresolved: NOT a known fix. This paragraph and the following fields concern only case #2938, not another case with similar symptoms.
Problem: Device serial number could not be found in inventory.
Recorded action: None recorded.
Recorded result: None recorded.
Scope: Vertex 2
Recorded equipment/software: [21000-2] Vertex (2)
Limits: Record lacks technical troubleshooting detail or resolution.
Provenance: Odoo support record 266; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3002: Unresolved: NOT a known fix
Exact source reference: support case #3002. Evidence classification: Unresolved: NOT a known fix. This paragraph and the following fields concern only case #3002, not another case with similar symptoms.
Problem: Vertex unit stopped populating data with an unverified serial number.
Recorded action: None recorded.
Recorded result: None recorded.
Scope: Vertex device functionality.
Recorded equipment/software: [68000-A] EL POS8
Limits: No outcome evidence provided.
Provenance: Odoo support record 330; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3106: Action recorded: resolution NOT established
Exact source reference: support case #3106. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #3106, not another case with similar symptoms.
Problem: CallerID works, but names are not populating; later issues with USB-Ethernet connectivity.
Recorded action: Configured phone setup; recommended specific switch purchase.
Recorded result: CallerID is working but needs PC/laptop with USB-Ethernet port to finish POS display configuration.
Scope: CallerID/network setup
Recorded equipment/software: [21000-2] Vertex (2) 路 Clover / Phone Orders Add on / Clover Network, INC.
Limits: Customer missing required hardware for final configuration.
Provenance: Odoo support record 434; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3180: Documented technical outcome
Exact source reference: support case #3180. Evidence classification: Documented technical outcome. This paragraph and the following fields concern only case #3180, not another case with similar symptoms.
Problem: Device failed to boot and serial loop test failed following power outage; damaged RS232 port chip identified.
Recorded action: Replaced damaged internal components including RS232 port chip IC9.
Recorded result: Device tested properly and is ready for return.
Scope: Vertex Whozz Calling 4 unit repair
Recorded equipment/software: [13000-A] WC4 Deluxe 路 Aldelo POS / ALDELO Pos Software
Provenance: Odoo support record 508; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3182: Unresolved: NOT a known fix
Exact source reference: support case #3182. Evidence classification: Unresolved: NOT a known fix. This paragraph and the following fields concern only case #3182, not another case with similar symptoms.
Problem: Unable to connect device due to missing USB to Ethernet adapter.
Recorded action: None performed.
Recorded result: Customer to follow up.
Scope: Hardware connectivity
Recorded equipment/software: [21000-4] Vertex (4)
Provenance: Odoo support record 510; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3198: Documented technical outcome
Exact source reference: support case #3198. Evidence classification: Documented technical outcome. This paragraph and the following fields concern only case #3198, not another case with similar symptoms.
Problem: Three amber lights were illuminated on the Vertex but no phone data was populating the POS screen.
Recorded action: Re-routed cables from Data output to Serial, captured SIP Gateway MAC address, and corrected bridge port connections.
Recorded result: All three amber lights illuminated and the Vertex serial data connection is working.
Scope: Hardware integration
Recorded equipment/software: [21000-4] Vertex (4) 路 Aldelo POS / ALDELO Pos Software
Provenance: Odoo support record 526; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3214: Action recorded: resolution NOT established
Exact source reference: support case #3214. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #3214, not another case with similar symptoms.
Problem: POS not receiving CallerID information via serial output, although unit detects calls.
Recorded action: Explained that VCT and POS cannot bind to the same COM port simultaneously; provided troubleshooting steps for testing.
Recorded result: Assumed serial port failure on the vertex, initiated warranty RMA.
Scope: Serial port integration.
Recorded equipment/software: [21000-4] Vertex (4) 路 Profitek / Infospec Systems
Limits: Confirmed serial failure unverified at bench.
Provenance: Odoo support record 542; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3227: Unresolved: NOT a known fix
Exact source reference: support case #3227. Evidence classification: Unresolved: NOT a known fix. This paragraph and the following fields concern only case #3227, not another case with similar symptoms.
Problem: Vertex not pushing data to POS serial port.
Recorded action: None.
Recorded result: None.
Scope: POS serial communication
Recorded equipment/software: [21000-2] Vertex (2)
Provenance: Odoo support record 555; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3243: Action recorded: resolution NOT established
Exact source reference: support case #3243. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #3243, not another case with similar symptoms.
Problem: Missing CallerID pop-ups; inconsistent serial data read.
Recorded action: Provided switch upgrade (TP-Link) and wiring instructions; suggested multi-step diagnostic test.
Recorded result: Awaiting customer call back for additional diagnostics.
Scope: POS/Network integration.
Recorded equipment/software: [21000-4] Vertex (4)
Limits: Outcome evidence missing.
Provenance: Odoo support record 571; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3261: Unresolved: NOT a known fix
Exact source reference: support case #3261. Evidence classification: Unresolved: NOT a known fix. This paragraph and the following fields concern only case #3261, not another case with similar symptoms.
Problem: Serial CallerID unit stopped working after upgrading the PC to Windows 10.
Recorded action: Provided a tech bulletin on network troubleshooting, but emphasized potential hardware obsolescence (9 years old).
Recorded result: No resolution found for the serial connectivity issue.
Scope: WC4 Deluxe hardware.
Recorded equipment/software: [13000-A] WC4 Deluxe 路 Aldelo POS / ALDELO Pos Software
Limits: The technician noted the unit is beyond its expected lifespan and did not troubleshoot the Windows 10 OS compatibility.
Provenance: Odoo support record 589; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3287: Action recorded: resolution NOT established
Exact source reference: support case #3287. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #3287, not another case with similar symptoms.
Problem: Vertex was connected to the data port instead of the gateway port; serial signal needed to be run to POS stations.
Recorded action: Instructed customer to relocate cables to the Towards Gateway port; recommended running Cat5 with serial adapters.
Recorded result: Customer is planning to pull required cabling.
Scope: Vertex (4) with Focus POS.
Recorded equipment/software: [21000-4] Vertex (4) 路 Focus / Focus POS Systems
Limits: Unresolved pending cabling installation.
Provenance: Odoo support record 615; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3303: Action recorded: resolution NOT established
Exact source reference: support case #3303. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #3303, not another case with similar symptoms.
Problem: Device was incorrectly configured for serial communication.
Recorded action: Provided installation instructions and guidance on configuring data output to serial.
Recorded result: Guidance provided to user.
Scope: System configuration
Recorded equipment/software: [21000-4] Vertex (4)
Limits: Support provided as out-of-warranty paid guidance.
Provenance: Odoo support record 631; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3322: Documented technical outcome
Exact source reference: support case #3322. Evidence classification: Documented technical outcome. This paragraph and the following fields concern only case #3322, not another case with similar symptoms.
Problem: Data not pushing to POS.
Recorded action: Screenshare to update data output from broadcast to serial.
Recorded result: All functioning correctly.
Scope: Configuration
Recorded equipment/software: [21000-4] Vertex (4) 路 Aloha/Aloha to GO / NCR Corporate
Provenance: Odoo support record 650; case evidence reviewed 04NOV26. Historical result, not a fresh site test.
Case #3337: Action recorded: resolution NOT established
Exact source reference: support case #3337. Evidence classification: Action recorded: resolution NOT established. This paragraph and the following fields concern only case #3337, not another case with similar symptoms.
Problem: Requires serial connection for Aloha POS; current setup uses ethernet.
Recorded action: Instructed user to acquire USB-to-ethernet adapter and schedule screen share.
Recorded result: Pending hardware acquisition by customer.
Scope: Vertex (4).
Recorded equipment/software: [21000-4] Vertex (4) 路 Aloha/Aloha to GO / NCR Corporate
Limits: Waiting for user hardware.
Provenance: Odoo support record 665; case evidence reviewed 04NOV26. Historical result, not a fresh site test.