Device Quick-Start Guide — All Models

Quick Navigation 1. Vertex (VoIP/Ethernet)

2. Whozz Calling POS — Serial (2, 4, 8 Line)

3. Whozz Calling POS — Ethernet (2, 4, 8 Line)

4. Whozz Calling Basic (2, 4, 8 Line — Serial)

5. Whozz Calling Deluxe (2, 4, 8 Line — Serial)

6. Model Comparison Chart

7. Universal Test Call Procedure

How to use this guide: Find your device model below. Each section covers everything you need to go from unboxing to your first verified caller ID capture in 10–15 minutes.

1. Vertex — VoIP / Ethernet Caller ID

Vertex Quick-Start Card

What’s in the Box

ItemQtyNotes

Vertex unit12, 4, or 8 channel model

9 V DC power adapter1Barrel connector

Ethernet patch cables (Cat5e)3For bridge ports + management port

Quick-start insert1Printed reference card

Rear-Panel Ports

Port LabelCableConnects To

Toward GatewayEthernetISP modem/router or main network switch (upstream)

To PhonesEthernetVoIP phone switch or phones (downstream)

ManagementEthernetNetwork switch on same subnet as POS system

SerialDB9 serialDirect serial connection (alternative to Management port)

Power9 V DC barrelIncluded power adapter

LED Indicators

LEDNormal StateMeaning

PowerSolid amberUnit powered and operational

VoIP Bridge 1Solid amber“Toward Gateway” port linked

VoIP Bridge 2Solid amber“To Phones” port linked

Any LED off—Cable not connected or link down — check cabling

All 3 amber LEDs must be solid ON before proceeding. If any LED is off, verify the Ethernet cable is seated and the connected device is powered.

First-Time Setup

1Connect cables (power OFF)

Plug “Toward Gateway” into the upstream switch/router.

Plug “To Phones” into the VoIP phone switch.

Plug “Management” into the POS/data network switch.

2Power on & verify LEDs

Connect the 9 V adapter. Confirm all 3 amber LEDs are solid ON.

3Set DIP switches (default for most installs)

SwitchPositionPurpose

1UPNormal operation

2DOWNEnable phone-based setup (firmware 140+)

3UPNormal operation

4UPNormal operation

4Configure via Vertex Configuration Tool or phone dialing

Web tool: Open the Vertex Configuration Tool in your browser, click Discover Devices, and follow the guided setup.

No-PC method: From a monitored VoIP phone, dial *00 to hear the current IP, then use *01–*09 commands to configure.

5Verify with a test call

Call in from a cell phone. Confirm the POS or monitoring software displays the caller ID within 2 rings.

Encrypted VoIP (TLS/SRTP): Vertex requires unencrypted SIP. If your VoIP provider encrypts calls, you will need an ATA adapter or EdgeMarc SBC to decrypt before the Vertex.

2. Whozz Calling POS — Serial (2, 4, 8 Line)

POS Serial Quick-Start Card

What’s in the Box

ItemQtyNotes

Whozz Calling POS unit12, 4, or 8 line model

9 V DC power adapter1Barrel connector

RJ11 phone cables2–8One per phone line

DB9 serial cable1Connects to POS computer COM port

RJ11 line duplicators2–8For parallel (tap) wiring

Physical Connections

PortCableConnects To

LINE 1–8 jacksRJ11Incoming analog phone lines (via line duplicator)

Serial (DB9)DB9 serialPOS computer COM port (or USB-to-serial adapter)

Power9 V DC barrelIncluded power adapter

LED Indicators

LEDNormal StateMeaning

PowerSolid greenUnit powered

Line 1–8Off (idle) / Solid (ringing/in-use)Lights when line activity detected

Line LED red flashBrief flashCaller ID data received on that line

First-Time Setup

1Connect phone lines

Attach a line duplicator to each wall jack.

One side of duplicator goes to the phone/PBX (as before).

Other side goes to the corresponding LINE jack on the POS unit.

2Connect serial cable

Plug the DB9 cable into the unit and into the POS computer’s COM port. If no COM port exists, use a USB-to-serial adapter and install its driver.

3Power on

Connect 9 V adapter. Green power LED lights immediately.

4Configure POS software

Open your POS application’s caller ID settings.

Select the correct COM port (e.g., COM3).

Set baud rate to 9600 (default for POS units).

Data bits: 8, Parity: None, Stop bits: 1 (8N1).

5Verify with a test call

Call in from a cell phone. Confirm caller ID appears on the POS screen within 2 rings.

Tip: If you don’t know which COM port to use, open Windows Device Manager → Ports (COM & LPT) to see assigned port numbers.

3. Whozz Calling POS — Ethernet (2, 4, 8 Line)

POS Ethernet Quick-Start Card

What’s in the Box

ItemQtyNotes

Whozz Calling POS Ethernet unit12, 4, or 8 line model (EL variant)

9 V DC power adapter1Barrel connector

RJ11 phone cables2–8One per phone line

Ethernet cable (Cat5e)1Connects to network switch

RJ11 line duplicators2–8For parallel (tap) wiring

Physical Connections

PortCableConnects To

LINE 1–8 jacksRJ11Incoming analog phone lines (via line duplicator)

Ethernet (RJ45)Cat5eNetwork switch on same subnet as POS computer

Power9 V DC barrelIncluded power adapter

LED Indicators

LEDNormal StateMeaning

PowerSolid greenUnit powered

Ethernet LinkSolid greenNetwork connection established

Line 1–8Off (idle) / Solid (ringing/in-use)Lights when line activity detected

First-Time Setup

1Connect phone lines

Same as POS Serial: use line duplicators to tap each incoming phone line into the corresponding LINE jack.

2Connect Ethernet

Plug the Cat5e cable from the unit’s Ethernet port into the same network switch used by the POS computer.

3Power on

Connect 9 V adapter. Power LED and Ethernet Link LED should both light green.

4Set IP address

By default the unit uses DHCP. If your network has a DHCP server, the unit will receive an IP automatically.

To assign a static IP, use the ELConfig utility (available at callerid.com/downloads) or the Vertex Configuration Tool.

Default UDP port: 3520.

5Configure POS software

In your POS caller ID settings, select Ethernet/Network mode.

Enter the unit’s IP address and port (3520).

Some POS systems auto-discover Ethernet units via UDP broadcast.

6Verify with a test call

Call in from a cell phone. Confirm caller ID appears on the POS screen.

Energy Efficient Ethernet (EEE): Some managed switches have EEE enabled by default, which can cause intermittent data loss. If caller ID is inconsistent, disable EEE on the switch port connected to the unit.

4. Whozz Calling Basic (2, 4, 8 Line — Serial)

Whozz Calling Basic Quick-Start Card

What’s in the Box

ItemQtyNotes

Whozz Calling Basic unit12, 4, or 8 line model

9 V DC power adapter1Barrel connector

RJ11 phone cables2–8One per phone line

DB9 serial cable1Connects to computer COM port

RJ11 line duplicators2–8For parallel (tap) wiring

Physical Connections

PortCableConnects To

LINE 1–8 jacksRJ11Incoming analog phone lines (parallel tap via duplicator)

Serial (DB9)DB9 serialComputer COM port or USB-to-serial adapter

Power9 V DC barrelIncluded power adapter

Basic vs Deluxe: The Basic unit captures incoming caller ID only. It connects in parallel (tap) and does not need to be wired in-line. This means you can disconnect it without affecting phone service.

LED Indicators

LEDNormal StateMeaning

PowerSolid greenUnit powered and ready

Line 1–8Off (idle) / Flash on ringFlashes when incoming ring detected on that line

First-Time Setup

1Connect phone lines (parallel tap)

Attach a line duplicator to each incoming phone wall jack.

One side continues to the phone or PBX as before.

The other side connects to the matching LINE jack on the Basic unit.

2Connect serial cable

Plug DB9 into the unit and into your computer. Use a USB-to-serial adapter if no native COM port is available.

3Power on

Connect 9 V adapter. Green power LED lights immediately. Verify dial tone still works on all phones.

4Configure software

Select the correct COM port in your caller ID software or POS system.

Baud rate: 9600 (default).

Settings: 8 data bits, No parity, 1 stop bit (8N1).

5Verify with a test call

Call in from a cell phone. The line LED should flash, and caller ID data should appear in your software.

5. Whozz Calling Deluxe (2, 4, 8 Line — Serial)

Whozz Calling Deluxe Quick-Start Card

What’s in the Box

ItemQtyNotes

Whozz Calling Deluxe unit12, 4, or 8 line model

9 V DC power adapter1Barrel connector

RJ11 phone cables4–16Two per line (LINE IN + LINE OUT)

DB9 serial cable1Connects to computer COM port

Physical Connections

PortCableConnects To

LINE IN 1–8RJ11Incoming phone lines from wall/demarc

LINE OUT 1–8RJ11Continues to phone, PBX, or key system

Serial (DB9)DB9 serialComputer COM port or USB-to-serial adapter

Power9 V DC barrelIncluded power adapter

In-Line Wiring Required: Unlike the Basic model, the Deluxe unit must be wired in-line (phone lines pass through the unit). This is required for outbound call logging and off-hook detection. Do NOT use line duplicators for the final installation.

LED Indicators

LEDNormal StateMeaning

PowerSolid greenUnit powered and ready

Line 1–8Off (idle) / Solid (off-hook)Solid when phone is off-hook; flashes on ring

First-Time Setup

1Connect phone lines IN-LINE

Disconnect the phone cable from the wall jack.

Connect wall jack → LINE IN on the Deluxe unit.

Connect LINE OUT → phone, PBX, or key system.

Repeat for each phone line.

2Connect serial cable

Plug DB9 into the unit and into your computer. Use a USB-to-serial adapter if needed.

3Power on

Connect 9 V adapter. Verify power LED is green and all phones still have dial tone.

4Configure software

Select the correct COM port in your caller ID software.

Baud rate: 9600 (default).

Settings: 8 data bits, No parity, 1 stop bit (8N1).

5Verify with a test call

Inbound test: Call in from a cell phone. Verify caller ID appears.

Outbound test: Pick up a monitored phone and dial a number. Verify the dialed digits are captured.

Duration test: Make a short call, hang up, and verify the call duration is logged.

Deluxe Extra Features

FeatureDescription

Outbound digit captureLogs digits dialed on outbound calls

Off-hook detectionDetects when handset is lifted

Call durationTracks elapsed time from pickup to hangup

Inbound caller IDSame as Basic — captures CNAM and number

6. Model Comparison Chart

Feature Vertex POS Serial POS Ethernet WC Basic WC Deluxe

Phone Line Type VoIP/SIP Analog (POTS) Analog (POTS) Analog (POTS) Analog (POTS)

Data Output Ethernet / Serial Serial (DB9) Ethernet (RJ45) Serial (DB9) Serial (DB9)

Inbound Caller ID Yes Yes Yes Yes Yes

Outbound Logging Yes No No No Yes

Off-Hook Detection Yes No No No Yes

Call Duration Yes No No No Yes

Wiring Method Network bridge Parallel (tap) Parallel (tap) Parallel (tap) In-line (pass-through)

Line Counts 2, 4, 8 2, 4, 8 2, 4, 8 2, 4, 8 2, 4, 8

Default Baud Rate N/A (Ethernet) 9600 N/A (Ethernet) 9600 9600

Default UDP Port 3520 N/A 3520 N/A N/A

Power 9 V DC 9 V DC 9 V DC 9 V DC 9 V DC

7. Universal Test Call Procedure

After completing any device setup, follow this procedure to confirm everything works:

1Prepare a test phone

Use a cell phone (not connected to the same phone system) so the caller ID is guaranteed to be delivered from the carrier.

2Open your monitoring software

Have the POS caller ID screen, HyperTerminal, or a serial monitor open and ready before placing the call.

3Place the test call

Call your monitored line from the cell phone. Let it ring at least 2 full rings before answering (caller ID is delivered between ring 1 and ring 2).

4Verify the data

You should see a data record similar to:

01 I S 0000 G  1 01/15 02:30 PM 770-555-1234   CELL PHONE

Confirm: line number, phone number, and caller name appear.

5Verify on each line

Repeat the test on every phone line connected to the unit. Each line should produce its own data record with the correct line number (01, 02, 03, etc.).

Installation complete! If all lines produce caller ID data, your device is fully operational.

Troubleshooting Quick Checks

Symptom Possible Cause & Fix

No data at all Check power LED is on. Verify serial/Ethernet cable is connected. Confirm correct COM port or IP address in software.

Data on some lines but not others Verify RJ11 cables are seated on the non-working lines. Test with a different phone line cable.

Caller ID shows “P” or “Private” The calling party has caller ID blocked. Test from a different phone with caller ID enabled.

Caller ID shows “O” or “Out of Area” The carrier is not delivering caller ID. Contact your phone provider to confirm caller ID service is active.

Checksum = “B” (bad) Line noise or signal degradation. Check wiring, try a shorter cable, or add a line filter.

Garbled/partial data (serial) Baud rate mismatch. Confirm both unit and software are set to 9600, 8N1.

Intermittent data (Ethernet) Disable Energy Efficient Ethernet (EEE) on the switch port. Check for IP address conflicts.

Vertex: no caller ID on VoIP VoIP traffic may be encrypted (TLS/SRTP). Vertex requires unencrypted SIP. Contact your VoIP provider or use an ATA adapter.

Deluxe: no outbound digits Unit must be wired in-line (not parallel). Verify LINE IN and LINE OUT are correctly connected.