📄 Bad Checksums and Line Noise

Bad Checksums and Line Noise

Symptoms

Data shows 'B' (bad) instead of 'G' (good) checksum. Caller ID data may be garbled or missing digits.

Causes and Solutions

  • DSL interference — Install DSL filters on all devices sharing the line
  • Long cable runs — Move device closer to demarc point
  • Multiple devices — Remove splitters, fax machines, and other devices from the line
  • Poor wiring — Check for corroded connections, replace damaged cables
  • Low ring voltage — PBX extensions may not provide standard ~90V ring voltage

Diagnostic Steps

  1. Connect device directly at demarc with no other equipment
  2. If checksums improve, add devices back one at a time to identify the noise source
  3. Contact telco if noise persists at the demarc — the issue may be in the outside plant