Table of Contents
When turned on for the first time, all setup toggles are set to their default values. The order of how the toggles are input or displayed is not important. They are stored in non-volatile memory; if the unit loses power, the toggles will remain set. To display the toggle settings at any time use the "V" command. On start-up, the "V" command will display:
Vx.x ECXUDASoBKT L=01 00/00 00:00:nn
Where Vx.x is the version number of the master processor firmware, ECXUDASoBKT are the setup toggles, L=01 is the line number of the first channel of the unit, 00/00 is the date, and 00:00:nn is the time of the internal time clock (in HH:MM:SS).
The default toggle settings below instruct the unit to monitor both inbound and outbound calls and report call records both at the beginning and the end of the call.
ECXUDASoBKT
These toggles can be changed at any time to support various applications such as Call Accounting, Integrated Voice Response (IVR) applications, Pop up screens, and Telephony Diagnostics. Toggles are changed by simply sending the unit the new toggle. In a terminal program, simply type the letter of the toggle (a carriage return <CR> is not necessary). The unit is designed to accept one toggle at a time. If a software application sends an initialization string of toggles to the unit, a short pause of at least 50 msec should be inserted between each toggle so the unit’s processor has enough time to write the toggle to memory
Copyright © 2010 CallerID.com